Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer |
Output Type: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical Features | Description | |
Input | Input AC voltage | 1AC 220V±15%,3AC 220V±15%,3AC 380V±15% |
Recommend pv input DC voltage range |
160~380VDC; 350~750VDC(Maximum input DC voltage:800VDC) |
|
Input frequency range | 47~63Hz | |
Power factor | ≥97% | |
Control performance | Control mode | V/F control,non-PG vector control(SVC),PG vector control(FVC) |
V/F control | Linear,multipoint,spuare V/F curve,V/F seperation | |
Operation command mode |
Keypad control,Terminal control,Serial communication control | |
Frequency Reference Source |
Digital,analog,pulse frequency,serial communication,multi-step speed,simple PLC and PID The combinaton of multi-modes and the different modes can be switched. |
|
Overload capacity | 150%rated current 60s,180%rated current 3s | |
Start torque | G type:0.5Hz/150%(SVC),OHz/180%(FVC) | |
Speed adjusting range | 1:100(SVC) ; 1:1000(FVC) | |
Speed control accuracy | ±0.5%(SVC); ±0.02%(FVC) | |
Automatic voltage regulation(AVR) |
Automatically maintain a constant output voltage when the voltage of electricity grid changes |
|
Protection function | Overvolatge protection,undervoltage protection,overcurrent proteciton,overload protection,overheat protection,overcurrent stall protection,overvoltage stall protection,phase-loss protection,over-speed detection,motor overheat protection,short-circuit protection. |
|
The specific function of solar pump inveter |
CVT or MPPT control mode,maximum power point tracking,light weak auto sleep,light strong auto wake up,pre-warning at weak light,underload pre-warning,pre-warning when full water,fault protection of water level sensor,low water level automatic run,etc. | |
Terminals | Input terminals | 6 programmable digital inputs,it can be extended to 4 digital inputs,one of which supports high speed pulse input; 1 analog volatge input 0~10VDC; 2 volatge input 0~10VDC or current input 0~20mA |
Output terminals | 1 open collector output ,it can be extened to 1 high speed pulse output; 2 relay outputs; 2 analog output:volatge output 0~10VDC or current output 0~20mA |
|
Human machine interface | LED Display | Can display setting frequency,output frequency,output voltage,output current,etc. |
Enviorment &Protection class | Protection class | IP20 |
Humidity&temperature | 90%RH or less(no-condensation),-10ºC~+40ºC.Inverter will be derated ifambien temperature exceeds 40ºC | |
Vibration | Under 20Hz9.8m/s(1G),Over 20Hz5.88m/s(0.6G) | |
Store environment | ≤1000M,indoor(no corrosive gas and liquid) | |
Store temperature | -20ºC~60ºC | |
Cooling Mode | Forced air-cooling |
Rich control methods and a new speed sensorless vector control(SVC) algorithm, bring better low-speed stability, stronger low-frequency
load capacity, and support
SVC torque control,support a variety of PG cards, which can be realize the closed-loop control of asynchronous motors with more powerful and
significantly improved motor control performance .
Torque limited to control
"Excavator" feature, automatically limits torque during operation to prevent frequent over current trips; vector mode can realize torque control.
Equipped with two sets of motor parameters, which can realize the switching control of two motors.
Speed sensorless vector control(SVC), speed sensor vector control(VC), V/F control
Straight line or S curve acceleration and deceleration mode, four kinds of acceleration and deceleration time can be selected through terminal.
10 kinds of main and auxiliary frequency sources, which can flexibly realize auxiliary frequency fine adjustment and frequency synthesis.
Multiple encoder types are available
Support differential encoder, UVW encoder, resolver
Two sets of 4-point input curves are added to the analog input for more flexible use
0.75~22KW built-in braking units of various specifications, if you need to stop quickly, you can directly connect the braking resistor.
Through the built-in PLC or control terminal to realize up to 16 segment speeds automatic cycle switching operation, retention time, acceleration
and deceleration of each segment speed can be adjusted
All series of built-in speed tracking function, multiple speed tracking modes, speed tracking adjustable.