DC to AC 45kw Solar Pump VFD

Product Details
Customization: Available
Application: High-performance Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer, AC Motors, Industry, Fans, Pumps
Output Type: Triple
Still deciding? Get samples of US$ 580/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (27)
  • DC to AC 45kw Solar Pump VFD
  • DC to AC 45kw Solar Pump VFD
  • DC to AC 45kw Solar Pump VFD
  • DC to AC 45kw Solar Pump VFD
  • DC to AC 45kw Solar Pump VFD
  • DC to AC 45kw Solar Pump VFD
Find Similar Products

Basic Info.

Model NO.
H129T40450XX0
Principle of Work
V/F Control Transducer
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
General Type
Brand
New Folinn
Warranty
2 Years
Certifications
CE/ISO9001:2015
Input Phase
DC/AC
Input Frequency
47~63Hz
Input Voltage
AC 380V /DC(350V~750V)
Rated Power
45kw
Ingress Protection
IP20
OEM,ODM
Accepted
Service
24h Online Service
Transport Package
Foam+Carton/Foam+Wooden Case
Specification
685x384x345(mm)
Trademark
New Folinn
Origin
China
HS Code
8504409999
Production Capacity
8000 Sets/Month

Packaging & Delivery

Package Size
41.00cm * 71.00cm * 46.00cm
Package Gross Weight
33.000kg
Lead Time
7 days (1 - 1 Set)
To be negotiated ( > 1 Set)

Product Description

 

 

Description
 

DC to AC 45kw Solar Pump VFD
DC to AC 45kw Solar Pump VFD
DC to AC 45kw Solar Pump VFD



H129 Series Solar Pump Inverter

H129 series solar water pump VFD is a high performance multi-function AC drive, especially for solar pump based on H1 series and BD330-PV, it has high performance vector control, combined with solar pump application control requirements, which can realize excellent PID control function, MPPT function(maximum power point tracking), light weak auto sleep, light intensity auto wake up, under load protection, water shortage alarm, etc.Easy wiring, easy operation.



Aplication 

 

 


DC to AC 45kw Solar Pump VFD

Solar water pumps




Technical Features
 

 ltem Description
 Input rated voltage 1AC220V±15%, 3AC220V±15%, 3AC380V±15%
rated frequency 47~63Hz
Recommend pv input DC voltage range DC 160V~380V(AC220V) DC 350V~750V (AC380V)
 Output voltage 0- rated input voltage
frequency 0Hz~1000Hz
overload capacity 150% rated current 60s,180% rated current 2s
 main control performance control mode V/F,SVC
modulation mode Space vector PWM modulation
motor type asynchronous motor, synchronous motor, single motor
( Please consult the manufacturer before purchasing)
start torque 0.5Hz/150% rated torque
speed adjusting range 1:100( speed sensorless)
frequency accuracy digital setting: max. frequency±0.01%;
 analog setting: max. frequency±1%
frequency resolution digital setting: max. frequency±0.01%;
 analog setting: max. frequency±1%
acceleration and deceleration curve line/S-curve;
current limiting Automatic current limitation during operation to prevent frequent overcurrent fault tripping
instant power down Support instant stop non- stop,1:100( speed sensorless)
function for solar pump Intelligent control mode,maximum power point tracking, light weak auto sleep, light strong auto wake up, Water shortage alarm
 function
 operation
command source keypad, terminal, communication
setting value source digital, analog, multi- step speed, communication
PID support main setting+PID
keyboard indicatorlight Power supply indication, operation indication, fault indication    ( normally on) water shortage indication ( flashing)
dial switch RUN/STOP
Protection function overcurrent, overvoltage, undervoltage, overheat, overload, phase loss, earth leakage, output short circuit protection, etc
Environment applicable place indoor, no direct sunlight, no dust, corrosive gas, combustible gas,
 oil mist, water vapor, water drop or salt, etc
altitude derating use if above 1000m, derating 10% for every 1000m increase.
environment temperature -10ºC~+40ºC( derating use if environment temperature is 40ºC~50ºC)
humidity 5%~90% RH, non-condensation
store temperature -40ºC ~+70ºC
vibration less than 5.9m/s²(0.6g)

 




 

 

Certificates
 

 

DC to AC 45kw Solar Pump VFD

ApDC to AC 45kw Solar Pump VFDpli


DC to AC 45kw Solar Pump VFDcation


About us
 

DC to AC 45kw Solar Pump VFD

 

DC to AC 45kw Solar Pump VFD

 

 

 

 

 

 

 

 

 

 

 

 

H1 Series Certificates

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

Application

 

 

 

DescriptionDescription

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H1 Series Certificates

 

 

 

 

 

 

 

 

 

 

Packaging & Shipping

 

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier