Technical Features | |||||||||
I/O Features |
Input Voltage Range | 1AC220V±15% 3AC220V±15% 3AC380V±15% | |||||||
Input Frequency Range | 47-63Hz | ||||||||
Output Voltage Range | 0~rated input voltage | ||||||||
Output Frequency Range | 0~200Hz | ||||||||
I/O Terminals |
Input Terminals | 6 programmable digital inputs, it can be extended to 3 digital inputs, 1 high speed pulse input; 1 analog volatge input, 0~10VDC; 1 volatge input 0~10VDC or current input 4~20mA |
|||||||
Out Terminals | 1 open collector output, it can be extened to 1 high speed pulse output; 2 relay outputs, it can be extended 4 relay outputs; 2 analog output: 1 volatge output 0~10VDC, it can be extended to current output 4~20mA, 1 volatage output 0~10VDC or current output 4~20mA |
||||||||
Control function | Control system: | High performance vector control inverter based on DSP | |||||||
Control Mode | V/F Control, sensorless vector control(SVC) | ||||||||
Frequency Reference Source | Digital, analog, pulse frequency, serial communication, multi-step speed, simple PLC and PID, The combinaton of multi-modes and the different modes can be switched. |
||||||||
Overload Capacity | G type: 150% rated current-60s, 180% rated current-10s P type: 120% rated current-60s, 150% rated current-10s |
||||||||
Start Torque | 0.5Hz/150%(SVC) | ||||||||
Speed Adjusting Range | 1: 100 (SVC) | ||||||||
Speed Accuracy | ±0.5%(SVC) | ||||||||
Carrier Frequency | 1.0 to 15.0kHz; Automatically adjust carrier frequency according to the load characteristics. | ||||||||
Resolution of Frequency setting | Digital setting: 0.01Hz Anolog setting: Maximum frequency X 0.1% | ||||||||
Torque Boost | Automatic torque boost; Manual torque boost 0~30% | ||||||||
Acc/DEC Mode | Linear, 2 types Acc/DEC times | ||||||||
DC Braking | Supports starting and stopping DC braking | ||||||||
Jogging control | Jog frequency range: 0.0Hz to max. Frequency; Jog Acc/DEC time: 0~3600.0s | ||||||||
Simple PLC and Multi-speed operation | Built-in PLC or control terminal, 16 steps speed can be set | ||||||||
Built-in PID | Easy to realize closed-loop control system for the process control. | ||||||||
Automatic voltage regulation(AVR) | Automatically maintain a constant output voltage when the voltage of electricity grid changes | ||||||||
Other Functions | Traverse control function: Multiple triangular pulse frequency control | ||||||||
Over-torque and under-torque detection function | |||||||||
Switchover function: Switch main / auxiliary frequency, run command, local / remote | |||||||||
None-stop when instantaneous power off | |||||||||
Common DC bus function: Multiple inverters can use a common DC bus | |||||||||
Speed traking function: Smoothly start the running motor | |||||||||
Timing control: Timing setting range 0~65535h | |||||||||
Jump frequency function, which prevents mechanical resonance and makes the system more stable and reliable; | |||||||||
Protection function: Overvolatge, undervoltage, overcurrent, overload, overheat, overcurrent stall, overvoltage stall, phase-failure, external fault, EEPROM store abnormalities, PID feedback abnormalities, communication error, etc. | |||||||||
Other functions: Parameter restore, parameter self-learning, slip compensation, energy saving, etc. | |||||||||
Display | LED Display | Can display: Setting frequency, output frequency, output voltage, output current etc. | |||||||
Environmental Constraint | Protection level | IP20 | |||||||
Temptemperature | -10ºC~+40ºC, it will be derated if ambient emperature exceeds 40ºC | ||||||||
Humidity | Below 90%RH (no condensation) | ||||||||
Vibration | ≤20Hz 9.8m/s(1G), ≥20Hz 5.88m/s(0.6G) | ||||||||
Altitude | Below 1000m, indoor(place without corrosive gas, liquid) | ||||||||
Storage temperature | -20ºC~+60ºC | ||||||||
Cooling type | Forced cooling |