Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 59/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
DZB200M Series High Performance Mini Economy General Purpose Inverters
Specification
1AC220V±15% 0.5kW~0.75kW
3AC220V±15% 0.55kW~0.75kW
3AC380V±15% 0.75kW~2.2kW
Technical Features | |||||||||
I/O Features |
Input Voltage Range | 1AC220V±15% 3AC220V±15% 3AC380V±15% 3AC660V±10% 3AC1140V±15% | |||||||
Input Frequency Range | 47-63Hz | ||||||||
Output Voltage Range | 0~rated input voltage | ||||||||
Output Frequency Range | 0~300Hz (>600Hz can be produce as request) | ||||||||
I/O Terminals |
Input Terminals | 8 programmable digital inputs,can be extended to 1 high speed pulse input; 2 programmable analog input: 1 volatge input 0~10V or current input 4~20mA |
|||||||
Output Terminals | 1 open collector output 1 relay outputs 1 analog output: it can be extended to current output 0/4~20mA or voltage output 0/2~10V |
||||||||
Control Mode | V/F Control | ||||||||
Frequency Reference Source | Digital,analog,pulse frequency,serial communication,multi-step speed simple PLC and PID, The combination of multi-modes and the different modes can be switched. |
||||||||
Overload Capacity | 150% rated current-60s,180% rated current-10s | ||||||||
Start Torque | 1.5Hz/150% | ||||||||
Speed Adjusting Range | 1:100 | ||||||||
Speed Accuracy | ±0.5% | ||||||||
Carrier Frequency | 1.0 to 15.0kHz;automatically adjust carrier frequency according to the load characteristics. | ||||||||
Resolution of Frequency setting | Digital setting:0.01Hz Anolog setting:maximum frequency x 0.1% | ||||||||
Torque Boost | Automatic torque boost;manual torque boost 0~30% | ||||||||
Acc/Dec Mode | Linear,2 types Acc/Dec times | ||||||||
DC Braking | Supports starting and stopping DC braking | ||||||||
Jogging control | Jog frequency range:0.0Hz to max.frequency; Jog Acc/Dec time:0~3600.0s | ||||||||
Simple PLC and Multi-speed operation | Built-in PLC or control terminal 8 steps speed can be set | ||||||||
Built-in PID | Easy to realize closed-loop control system for the process control. | ||||||||
Automatic voltage regulation(AVR) | Automatically maintain a constant output voltage when the voltage of electricity grid changes | ||||||||
Other Functions | Traverse control function:multiple triangular pulse frequency control | ||||||||
Over-torque and under-torque detection function | |||||||||
None-stop when instantaneous power off | |||||||||
Common DC bus function: multiple inverters can use a common DC bus | |||||||||
Speed traking function: Smoothly start the running motor | |||||||||
Jump frequency function,which prevents mechanical resonance and makes the system more stable and reliable; | |||||||||
Protection function: overvolatge,undervoltage,overcurrent,overload,overheat,overcurrent stall,overvoltage stall,phase-failure,external fault,EEPROM store abnormalities,PID feedback abnormalities,communication error,etc. | |||||||||
Other functions:parameter restore,parameter self-learning,slip compensation,energy saving,etc. | |||||||||
Display | LED Display | Can display: setting frequency,output frequency,output voltage,output current etc. | |||||||
Environmental Constraint | Protection level | IP20 | |||||||
Temptemperature | -10ºC~+40ºC,it will be derated if ambient emperature exceeds 40ºC | ||||||||
Humidity | Below 90%RH (no condensation) | ||||||||
Vibration | ≤20Hz 9.8m/s(1G), ≥20Hz 5.88m/s(0.6G) | ||||||||
Altitude | Below 1000m,indoor(place without corrosive gas, liquid) | ||||||||
Storage temperature | -20ºC~+60ºC | ||||||||
Cooling type | Forced cooling |
Why choose Folinn?
Contact person:
MIchael
Director of Foreign Business